ASTM-D8000 Standard Practice for Flow Conditioning of Natural Gas and Liquids

ASTM-D8000 - 2015 R20 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Flow Conditioning of Natural Gas and Liquids
ORDER

Price:

$76.00        


Want this as a site license?

Scope

1.1 This practice covers flow conditioners that produce a fully developed flow profile for liquid and gas phase fluid flow for circular duct sizes 1- to 60-in. (25.4- to 1525-mm) diameter and Reynolds Number (Re) ranges from transition (100) to 100 000 000. These flow conditioners can be used for any type of flow meter or development of a fully developed flow profile for other uses.

1.2 The central single-hole configuration that is derived using fundamental screen theory is referenced as the flow conditioner described herein.

1.3 Piping lengths upstream and downstream of a flow conditioner are considered a critical component of a flow conditioner and constitute the complete flow conditioner system.

1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

4.1 Flow conditioners are used for the conditioning of the turbulent flow profile of gases or liquids to reduce the ADD (velocity profile distortion) DEL (turbulence), swirl, or irregularities caused by the installation effects of piping elbows, length of pipe, valves, tees, and other such equipment or piping configurations that will affect the reading of flow measurement meters thus inducing measurement errors as a result of the flow profile of the gas or liquid not having a fully developed flow profile at the measurement point.4

Keywords

annuli; axi-symmetric distribution; flow conditioners; flow profile; liquid; natural gas; screen theory; velocity profile;

To find similar documents by ASTM Volume:

05.06 (Gaseous Fuels; Coal and Coke)

To find similar documents by classification:

17.120.10 (Flow in closed conduits Gas meters in buildings, see 91.140.40 Water meters in buildings, see 91.140.60)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D8000-15R20

Revision Level

2015 R20 EDITION

Status

Current

Modification Type

New

Publication Date

Dec. 14, 2020

Document Type

Practice

Committee Number

D03.12