ASTM-C876 › Standard Test Method for Corrosion Potentials of Uncoated Reinforcing Steel in Concrete
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method covers the estimation of the electrical half-cell potential of uncoated reinforcing steel in field and laboratory concrete, for the purpose of determining the corrosion activity of the reinforcing steel.
1.2 This test method is limited by electrical circuitry. A concrete surface that has dried to the extent that it is a dielectric and surfaces that are coated with a dielectric material will not provide an acceptable electrical circuit. The basic configuration of the electrical circuit is shown in Fig. 1.
1.3 The values stated in inch-pound units are to be regarded as the standard.
1.4 This standard does not purport to address the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
concrete-corrosion activity; concrete-corrosion of reinforcing steel; corrosion activity; electrical half-cell potentials; half-cell potentials; ICS Number Code 77.140.15 (Steels for reinforcement of concrete)
To find similar documents by ASTM Volume:
03.02 (Corrosion of Metals; Wear and Erosion)
04.02 (Concrete and Aggregates)
To find similar documents by classification:
77.140.15 (Steels for reinforcement of concrete)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C0876-22B
Revision Level
2022B EDITION
Status
Current
Modification Type
Withdrawn
Publication Date
Oct. 11, 2022
Document Type
Test Method
Page Count
8 pages
Committee Number
G01.14