SS-ISO-16063-15 › Methods for the calibration of vibration and shock transducers - Part 15: Primary angular vibration calibration by laser interferometry (ISO 16063-15:2006, IDT)
SS-ISO-16063-15
-
2018 EDITION
-
CURRENT
Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:
The following bibliographic material is provided to assist you with your purchasing decision:
This part of ISO 16063 specifies the instrumentation and procedures used for primary angular vibration calibration of angular transducers, i.e. angular accelerometers, angular velocity transducers and rotational angle transducers (with or without amplifier) to obtain the magnitude and the phase shift of the complex sensitivity by steady-state sinusoidal vibration and laser interferometry. The methods specified in this part of ISO 16063 are applicable to measuring instruments (rotational laser vibrometers in particular) and to angular transducers as defined in ISO 2041 for the quantities of rotational angle, angular velocity and angular acceleration. It is applicable to a frequency range from 1 Hz to 1,6 kHz and a dynamic range (amplitude) from 0,1 rad/s2 to 1 000 rad/s2 (frequency-dependent). These ranges are covered with the uncertainty of measurement specified in Clause 3. Calibration frequencies lower than 1 Hz (e.g. 0,4 Hz, which is a reference frequency used in other International Standards) and angular acceleration amplitudes smaller than 0,1 rad/s2 can be achieved using method 3A or method 3B specified in this part of ISO 16063, in conjunction with an appropriate low-frequency angular vibration generator. Method 1A (cf. Clause 8: fringe-counting, interferometer type A) and method 1B (cf. Clause 8: fringe-counting, interferometer type B) are applicable to the calibration of the magnitude of complex sensitivity in the frequency range of 1 Hz to 800 Hz and under special conditions, at higher frequencies. Method 2A (cf. Clause 9: minimum-point method, interferometer type A) and method 2B (cf. Clause 9: minimum-point method, interferometer type B) can be used for sensitivity magnitude calibration in the frequency range of 800 Hz to 1,6 kHz. Method 3A (cf. Clause 10: sine-approximation method, interferometer type A) and method 3B (cf. Clause 10: sine-approximation method, interferometer type B) can be used for magnitude of sensitivity and ph...
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Designation Name
SS-ISO 16063-15:2018
Revision Level
2018 EDITION
Status
Current
Publication Date
Sept. 11, 2018
Language(s)
English
Page Count
56
International Equivalent
ISO 16063-15:2006(IDT)