SS-EN-ISO-10846-4 › Acoustics and vibration - Laboratory measurement of vibro-acoustic transfer properties of resilient elements - Part 4: Dynamic stiffness of elements other than resilient supports for translatory motion (ISO 10846-4:2003)
SS-EN-ISO-10846-4
-
EDITION 1
-
CURRENT
Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:
The following bibliographic material is provided to assist you with your purchasing decision:
This part of ISO 10846 specifies two methods for determining the dynamic transfer stiffness for translations of resilient elements other than resilient supports. Examples are resilient bellows, shaft couplings, power supply cables, hoses and pipe hangers (see Figure 1). Elements filled with liquids, such as oil or water, are excluded. NOTE 1 Pipe hangers are extensionally deflected, as opposed to elastic supports which are compressed. Therefore, the test conditions are different from those described in ISO 10846-2 and ISO 10846-3. The methods are applicable to resilient elements with flat flanges or flat clamp interfaces. It is not necessary that the flanges be parallel. Resilient elements which are the subject of this part of ISO 10846 are those that are used to reduce a) the transmission of audiofrequency vibrations (structure-borne sound, 20 Hz to 20 kHz ) to a structure which may, for example, radiate unwanted sound (airborne, waterborne or other), and b) the transmission of low-frequency vibrations (typically 1 Hz to 80 Hz), which may, for example, act upon human subjects or cause damage to structures of any size when the vibration is too severe. In practice, the size of the available test rig(s) determines restrictions for very small and for very large resilient elements. Measurements for translations normal and transverse to the flanges or clamp interfaces are covered in this part of ISO 10846. Annex A provides guidance for the measurement of transfer stiffnesses that include rotatory components. The direct method can be applied in the frequency range from 1 Hz up to a frequency that is usually determined by the lowest resonance frequency of the test arrangement frame (typically 300 Hz for test rigs with dimensions of the order of 1 m). NOTE 2 In practice, the lower frequency limit depends on the dynamic excitation system.
To find similar documents by classification:
17.140.01 (Acoustic measurements and noise abatement in general Including acoustic insulation)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Designation Name
SS-EN ISO 10846-4
Revision Level
EDITION 1
Status
Current
Publication Date
Oct. 3, 2003
Language(s)
English
Page Count
38
International Equivalent
EN ISO 10846-4:2003 IDT* ISO 10846-4:2003 IDT