ISO-10077-2 › Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames
The following bibliographic material is provided to assist you with your purchasing decision:
ISO 10077-2:2017 specifies a method and gives reference input data for the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazing or opaque panels.
The method can also be used to evaluate the thermal resistance of shutter profiles and the thermal characteristics of roller shutter boxes and similar components (e.g. blinds).
ISO 10077-2:2017 also gives criteria for the validation of numerical methods used for the calculation.
ISO 10077-2:2017 does not include effects of solar radiation, heat transfer caused by air leakage or three-dimensional heat transfer such as pinpoint metallic connections. Thermal bridge effects between the frame and the building structure are not included.
NOTE Table 1 in the Introduction shows the relative position of ISO 10077-2:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ISO 10077-2:2017
Revision Level
3RD EDITION
Status
Current
Publication Date
June 1, 2017
Committee Number