IEC-62990-1 Workplace atmospheres - Part 1: Gas detectors . Performance requirements of detectors for toxic gases

IEC-62990-1 - EDITION 1.0 - CURRENT


Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Included in this current edition are the following subparts:

 EDITION 1.0 - June 1, 2019
 ED. 1.0 CORRIGENDUM 1 - Dec. 1, 2019

IEC 62990-1:2019 specifies general requirements for design, function and performance, and describes the test methods that apply to portable, transportable, and fixed equipment for the detection and concentration measurement of toxic gases and vapours in workplace atmospheres and other industrial and commercial applications.
This document is applicable to continuously sensing equipment whose primary purpose is to provide an indication, alarm and/or other output function the purpose of which is to indicate the presence of a toxic gas or vapour in the atmosphere and in some cases to initiate automatic or manual protective action(s). It is applicable to equipment in which the sensor generates an electrical signal when gas is present.
This document applies to two types of equipment:
. Type HM (Health Monitoring) .occupational exposure. equipment:
For occupational exposure measurement, the performance requirements are focused on uncertainty of measurement of gas concentrations in the region of Occupational Exposure Limit Values (OELV). The upper limit of measurement will be defined by the manufacturer in accordance with 4.2.1.
. Type SM (Safety Monitoring) .general gas detection. equipment:
For general gas detection applications (e.g. safety warning, leak detection), the performance requirements are focused on alarm signalling. The upper limit of measurement will be defined by the manufacturer according to the intended use of the equipment.
In general, the requirements for accuracy will be higher for Type HM equipment than for Type SM equipment. The same equipment may meet the requirements of both Type HM and Type SM.
For equipment used for sensing the presence of multiple gases this document applies only to the detection of toxic gas or vapour.
This document is not applicable to equipment:
. with samplers and concentrators such as sorbents or paper tape having an irreversible indication;
. used for the measurement of gases and vapours related to the risk of explosion;
. used for the measurement of oxygen;
. used only in laboratories for analysis or measurement;
. used only for process measurement purposes;
. used in the domestic environment;
. used in environmental air pollution monitoring;
. used for open-path (line of sight) area gas measurement;
. used for ventilation control in car parks or tunnels.
ORDER

Price:

$430.68        


Want this as a site license?

To find similar documents by classification:

29.260.20 (Electrical apparatus for explosive atmospheres)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

IEC 62990-1 Ed. 1.0 b:2019

Revision Level

EDITION 1.0

Status

Current

Publication Date

June 1, 2019

Committee Number

31