IEC-61810-2-1 › Electromechanical elementary relays - Part 2-1: Reliability - Procedure for the verification of B10 values
Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:
The following bibliographic material is provided to assist you with your purchasing decision:
IEC 61810-2-1:2017 specifies reliability test procedures for electromechanical elementary relays when enhanced requirements for the verification of reliability apply.
Particular provisions are given for relays incorporated in safety-related control systems of machinery in accordance with IEC 62061 and ISO 13849-1. For such relays, B10 values for dangerous failures (B10D values) are derived from the tests specified in this document.
This edition includes the following significant technical changes with respect to the previous edition:
- limitation of tests to 10 M cycles in Clause 5;
- reduction of required number of test samples to 5 in specified cases;
- introduction of WeiBayes analysis for routine test under Clause 4.
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
IEC 61810-2-1 Ed. 2.0 b:2017
Revision Level
EDITION 2.0
Status
Current
Publication Date
May 1, 2017
Committee Number
94