ASTM-E576 › Standard Test Method for Frost/Dew Point of Sealed Insulating Glass Units in the Vertical Position
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method describes a field or laboratory procedure for determining the frost point within the air space(s) of sealed insulating glass units, and establishes the criteria for determining whether that point is below or above a given or specified temperature.
1.2 This test method also describes the apparatus to be used for these determinations.
1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Notes 2 and 3.
Keywords
Dew/frost point; sealed insulating glass units (in vertical position), test,; Glass-insulating materials (thermal); thermal insulating materials-glass; dew/frost point (of sealed insulating glass units in vertical position); ICS Number Code 91.060.50 (Doors and windows)
To find similar documents by ASTM Volume:
04.11 (Building Constructions (I): E72 - E2110)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-E0576-14R20
Revision Level
2014 R20 EDITION
Status
Current
Publication Date
May 4, 2020
Document Type
Test Method
Page Count
10 pages
Committee Number
E06.22