ASTM-E3087 › Standard Test Method for Measuring Capture Efficiency of Domestic Range Hoods
The following bibliographic material is provided to assist you with your purchasing decision:
Changes from the previous issue
A redline edition is available for this document, with all changes visible. Ask Document Center Inc. for more information.
Scope
1.1 This test method measures the capture efficiency of wall-mounted domestic range hoods under controlled conditions in a test chamber.
1.2 This test method applies to range hoods that exhaust air to outside and does not apply to recirculating range hoods.
1.3 This test method only applies to range hood air flows up to 200 L/s and widths up to 0.91 m (36 in.).
1.4 This test method is intended to quantify the capture efficiency of range hoods under controlled laboratory conditions suitable for rating.
1.5 The values stated in SI units are to be regarded as standard. If a value for measurement is followed by a value in other units in parentheses, the second value may be approximate. The first stated value is the requirement.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Significance and Use
5.1 Cooking can be one of the most polluting activities commonly and regularly occurring in residential environments. Capturing airborne cooking contaminants before they can mix with the indoor air is a critical indoor air quality control method.
5.2 Range hoods are used in homes to remove cooking-generated contaminants above cooking surfaces before they mix with air in the rest of the house. This test method is used to measure the capture efficiency under specific conditions that permit comparisons and ratings of range hoods.
5.3 Range hoods may be manufactured and intended to operate at different flow rates or using different inserts such as filters. This test method may be used to determine capture efficiency over the range of rated air flows and operating configurations of a range hood. The rated air flows shall be listed and shall be tested in accordance with HVI Test Procedure 916, IEC 61591, ASHRAE 51/AMCA 210, or equivalent. The maximum air flow allowed for this test method is 200 L/s.
Keywords
IAQ; kitchen ventilation; range hood; residential; tracer gas;; ICS Number Code 97.040.20 (Cooking ranges, working tables, ovens and similar appliances)
To find similar documents by ASTM Volume:
13.02 (Emergency Medical Services; Search and Rescue; Anesthetic and Respiratory Equipment)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-E3087-18
Revision Level
2018 EDITION
Status
Current
Modification Type
Revision
Publication Date
Oct. 1, 2018
Document Type
Test Method
Page Count
7 pages
Committee Number
E06.41