ASTM-D6834 › Standard Test Method for Determining Product Leakage from a Package with a Mechanical Pump Dispenser (Withdrawn 2017)
The following bibliographic material is provided to assist you with your purchasing decision:
This test method covers the evaluation of the sealing ability of a mechanical pump dispenser when packaging is held under vacuum and evaluation of the actual seal between the pump dispenser and the neck container/closure integrity. Apparatus for this test method include a vacuum chamber capable of handling pressure within the prescribed range and absorbent paper. Test specimens should be collected and conditioned according to the requirements. Procedures include a product leakage test without vibration testing of a mechanical pump dispenser package and a product leakage test with vibration testing of a mechanical pump dispenser package.
Scope
1.1 This test method covers the evaluation of the ability of a pump dispenser to seal when the packaging is held under vacuum. Furthermore, it evaluates the seal between the pump dispenser and the neck container/closure integrity.
1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
See 4.3 for a specific warning statement.
Significance and Use
This test method is suitable for establishing specifications of product leakage for both the pump dispenser and the final package. The test is performed at two levels of vacuum, a low and a high level, in order to avoid going directly from atmospheric pressure to 200 mbar, which can sometimes cause pump components that had not been fully seated, to seat.
Method A, Product Leakage Test without Vibration Testing of a Mechanical Pump Dispenser Package, is used when a pre-conditioning of the package in a simulated shipping situation is not desired.
Method B, Product Leakage Test with Vibration Testing of a Mechanical Pump Dispenser Package, is used when a pre-conditioning of the package in a simulated shipping situation is desired. The dynamics and stresses of shipping can create conditions where the package may be more likely to leak.
Keywords
container leakage; mechanical pump dispenser leakage; vacuum leakage test; Container leakage; Leak testing; Mechanical pump dispensers; Neck container/closure integrity; Product leakage testing; Vacuum leak test; ICS Number Code 55.020 (Packaging and distibution of goods in general)
To find similar documents by ASTM Volume:
15.10 (Packaging; Flexible Barrier Packaging)
To find similar documents by classification:
55.020 (Packaging and distribution of goods in general)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D6834-02(2008)
Revision Level
2002 R08 EDITION
Status
Superseded
Modification Type
Withdrawn
Publication Date
Nov. 1, 2008
Document Type
Test Method
Page Count
3 pages
Committee Number
F02.40