ASTM-D6103 › Standard Test Method for Flow Consistency of Controlled Low Strength Material (CLSM)
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method covers the procedure for determination of the flow consistency of fresh Controlled Low Strength Material (CLSM). This test method applies to flowable CLSM with a maximum particle size of 19.0 mm (3/4 in.) sieve.
1.2 The values stated in SI units are to be regarded as standard. The inch-pound equivalents are given for information only.
1.3 CLSM is also known as flowable fill, controlled density fill, soil-cement grout, unshrinkable fill, K-Krete, and other similar names.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use
This test method is intended to provide the user with a procedure to determine the fluidity of CLSM mixtures for use as backfill or structural fill.
This test method is considered applicable to fresh CLSM containing only sand as the aggregate or having coarse aggregate smaller than 19.0 mm (¾ in.). If the coarse aggregate is larger than 19.0 mm (¾in.), the test method is applicable when it is made on the fraction of CLSM passing a 19.0 mm (¾ in.) sieve, with the larger aggregate being removed in accordance with the section on Additional Procedures for Large Maximum size Aggregate Concrete in Practice C 172
Note 1—Removing the coarse aggregate will alter the characteristics of the mix and therefore will give information only about the remaining material. It is suggested that for mixes containing coarse aggregate 19.0 mm ( ¾ in.) or larger, a measurement of the slump is more appropriate.
For non-flowable CLSM, or for mixtures that do not come out of the flow cylinder easily, measure the slump as outlined in Test Method C 143
This test method is one of a series of quality control tests that can be performed on CLSM during construction to monitor compliance with specification requirements. The other tests that can be used during construction control are Test Methods D 4832
Note 2—The quality of the result produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D 3740
Keywords
backfill; CLSM; construction control; flowable fill; flow consistency; flow cylinder; mix design; quality control; soil stabilization; ICS Number Code 91.100.99 (Other construction materials)
To find similar documents by ASTM Volume:
04.09 (Soil and Rock (II): D5877 - latest)
To find similar documents by classification:
91.100.99 (Other construction materials)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASTM-C796Standard Test Method for Foaming Agents for Use in Producing Cellular Concrete Using Preformed Foam
ASTM-D2434
Standard Test Methods for Measurement of Hydraulic Conductivity of Coarse-Grained Soils
ASTM-C869
Standard Specification for Foaming Agents Used in Making Preformed Foam for Cellular Concrete
Document Number
ASTM-D6103_D6103M-17E01
Revision Level
2017(E1) EDITION
Status
Current
Modification Type
Withdrawn
Publication Date
June 25, 2021
Document Type
Test Method
Page Count
4 pages
Committee Number
D18.15