ASTM-C1718 › Standard Test Method for Nondestructive Assay of Radioactive Material by Tomographic Gamma Scanning
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method describes the nondestructive assay (NDA) of gamma ray emitting radionuclides inside containers using tomographic gamma scanning (TGS). High resolution gamma ray spectroscopy is used to detect and quantify the radionuclides of interest. The attenuation of an external gamma ray transmission source is used to correct the measurement of the emission gamma rays from radionuclides to arrive at a quantitative determination of the radionuclides present in the item.
1.2 The TGS technique covered by the test method may be used to assay scrap or waste material in cans or drums in the 1 to 500 litre volume range. Other items may be assayed as well.
1.3 The test method will cover two implementations of the TGS procedure: (1) Isotope Specific Calibration that uses standards of known radionuclide masses (or activities) to determine system response in a mass (or activity) versus corrected count rate calibration, that applies to only those specific radionuclides for which it is calibrated, and (2) Response Curve Calibration that uses gamma ray standards to determine system response as a function of gamma ray energy and thereby establishes calibration for all gamma emitting radionuclides of interest.
1.4 This test method will also include a technique to extend the range of calibration above and below the extremes of the measured calibration data.
1.5 The assay technique covered by the test method is applicable to a wide range of item sizes, and for a wide range of matrix attenuation. The matrix attenuation is a function of the matrix composition, photon energy, and the matrix density. The matrix types that can be assayed range from light combustibles to cemented sludge or concrete. It is particularly well suited for items that have heterogeneous matrix material and non-uniform radioisotope distributions. Measured transmission values should be available to permit valid attenuation corrections, but are not needed for all volume elements in the container, for example, if interpolation is justified.
1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Significance and Use
5.1 The TGS provides a nondestructive means of mapping the attenuation characteristics and the distribution of the radionuclide content of items on a voxel by voxel basis. Typically in a TGS analysis a vertical layer (or segment) of an item will be divided into a number of voxels. By comparison, a segmented gamma scanner (SGS) can determine matrix attenuation and radionuclide concentrations only on a segment by segment basis.
5.2 It has been successfully used to quantify 238Pu, 239Pu, and 235U. SNM loadings from 0.5 g to 200 g of 239Pu (5, 6), from 1 g to 25 g of 235U (7), and from 0.1 to 1 g of 238Pu have been successfully measured. The TGS technique has also been applied to assaying radioactive waste generated by nuclear power plants (NPP). Radioactive waste from NPP is dominated by activation products (for example, 54Mn, 58Co, 60Co, 110mAg) and fission products (for example, 137Cs, 134Cs). The radionuclide activities measured in NPP waste is in the range from 3.7E+04 Bq to 1.0E+07 Bq. Some results of TGS application to non-SNM radionuclides can be found in the literature (8).
5.3 The TGS technique is well suited for assaying items that have heterogeneous matrices and that contain a non-uniform radionuclide distribution.
5.4 Since the analysis results are obtained on a voxel by voxel basis, the TGS technique can in many situations yield more accurate results when compared to other gamma ray techniques such as SGS.
5.5 In determining the radionuclide distribution inside an item, the TGS analysis explicitly takes into account the cross talk between various vertical layers of the item.
5.6 The TGS analysis technique uses a material basis set method that does not require the user to select a mass attenuation curve apriori, provided the transmission source has at least 2 gamma lines that span the energy range of interest.
5.7 A commercially available TGS system consists of building blocks that can easily be configured to operate the system in the SGS mode or in a far-field geometry.
5.8 The TGS provides 3-dimensional maps of gamma ray attenuation and radionuclide concentration within an item that can be used as a diagnostic tool.
5.9 Item preparation is limited to avoiding large quantities of heavily attenuating materials (such as lead shielding) in order to allow sufficient transmission through the container and the matrix.
Keywords
ICS Number Code 13.030.30 (Special wastes); 17.240 (Radiation measurements); 27.120.30 (Fissile materials and nuclear fuel technology)
To find similar documents by ASTM Volume:
To find similar documents by classification:
17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C1718-10(2019)
Revision Level
2010 R19 EDITION
Status
Current
Modification Type
Reapproval
Publication Date
Feb. 1, 2019
Document Type
Test Method
Page Count
14 pages
Committee Number
C26.10