ASTM-C1071 › Standard Specification for Fibrous Glass Duct Lining Insulation (Thermal and Sound Absorbing Material)
The following bibliographic material is provided to assist you with your purchasing decision:
This specification covers fibrous glass insulation used as a thermal and sound absorbing liner for interior surfaces of ducts, plenums, and other air handling equipment. The insulation shall be of the following types: Type I and Type II. The basic material shall be made from glass processed from the molten state into fibrous form with a binder added to form dimensionally stable insulation. The following test methods shall be performed: corrosiveness; water vapor sorption; fungi resistance; temperature resistance; erosion resistance; odor emission; surface burning characteristics; apparent thermal conductivity; sound absorption coefficients; bacteria resistance; and combustion characteristics.
Changes from the previous issue
A redline edition is available for this document, with all changes visible. Ask Document Center Inc. for more information.
Scope
1.1 This specification covers fibrous glass insulation used as a thermal and sound absorbing liner for interior surfaces of ducts, plenums, and other air handling equipment that handle air up to 250°F (121°C).
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Keywords
duct; duct lining; fibrous glass; plenum; sound absorbing insulation; thermal insulation;; ICS Number Code 91.120.10 (Thermal insulation of buildings); 91.120.20 (Acoustics in buildings. Sound insulation)
To find similar documents by ASTM Volume:
04.06 (Thermal Insulation; Building and Environmental Acoustics)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASTM-A1008Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable
ASTM-A1011
Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength
ASTM-B124
Standard Specification for Copper and Copper Alloy Forging Rod, Bar, and Shapes
Document Number
ASTM-C1071-19
Revision Level
2019 EDITION
Status
Current
Modification Type
Revision
Publication Date
March 11, 2019
Document Type
Specification
Page Count
4 pages
Committee Number
C16.23