SS-ISO-4037-3 Radiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence (ISO 4037-3:2019, IDT)

SS-ISO-4037-3 - 2019 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This document specifies additional procedures and data for the calibration of dosemeters and doserate meters used for individual and area monitoring in radiation protection. The general procedure for the calibration and the determination of the response of radiation protection dose(rate)meters is described in ISO 29661 and is followed as far as possible. For this purpose, the photon reference radiation fields with mean energies between 8 keV and 9 MeV, as specified in ISO 4037-1, are used. In Annex D some additional information on reference conditions, required standard test conditions and effects associated with electron ranges are given. For individual monitoring, both whole body and extremity dosemeters are covered and for area monitoring, both portable and installed dose(rate)meters are covered. Charged particle equilibrium is needed for the reference fields although this is not always established in the workplace fields for which the dosemeter should be calibrated. This is especially true at photon energies without inherent charged particle equilibrium at the reference depth d, which depends on the actual combination of energy and reference depth d. Electrons of energies above 65 keV, 0,75 MeV and 2,1 MeV can just penetrate 0,07 mm, 3 mm and 10 mm of ICRU tissue, respectively, and the radiation qualities with photon energies above these values are considered as radiation qualities without inherent charged particle equilibrium for the quantities defined at these depths. This document also deals with the determination of the response as a function of photon energy and angle of radiation incidence. Such measurements can represent part of a type test in the course of which the effect of further influence quantities on the response is examined. This document is only applicable for air kerma rates above 1 µGy/h. This document does not cover the in-situ calibration of fixed installed area dosemeters. The procedures to be followed for the differe...

To find similar documents by classification:

01.110 (Technical product documentation Including rules for preparation of user guides, manuals, product specifications, etc.)

13.040.01 (Air quality in general)

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

27.120.01 (Nuclear energy in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

ORDER

Price:

$219.75        


Want this as a site license?



Designation Name

SS-ISO 4037-3:2019

Revision Level

2019 EDITION

Status

Current

Publication Date

March 13, 2019

Language(s)

English

Page Count

84

International Equivalent

ISO 4037-3:2019(IDT)