SS-EN-ISO-10993-6 Biological evaluation of medical devices - Part 6: Tests for local effects after implantation (ISO 10993-6:2016)

SS-EN-ISO-10993-6 - 2017 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


ISO 10993-6:2016 specifies test methods for the assessment of the local effects after implantation of biomaterials intended for use in medical devices. ISO 10993-6:2016 applies to materials that are - solid and non-absorbable, - non-solid, such as porous materials, liquids, gels, pastes, and particulates, and - degradable and/or absorbable, which may be solid or non-solid. The test sample is implanted into a site and animal species appropriate for the evaluation of the biological safety of the material. These implantation tests are not intended to evaluate or determine the performance of the test sample in terms of mechanical or functional loading. This part of ISO 10993 can also be applied to medical devices that are intended to be used topically in clinical indications where the surface or lining might have been breached, in order to evaluate local tissue responses. The local effects are evaluated by a comparison of the tissue response caused by a test sample to that caused by control materials used in medical devices whose clinical acceptability and biocompatibility characteristics have been established. The objective of the test methods is to characterize the history and evolution of the tissue response after implantation of a medical device/biomaterial including final integration or absorption/degradation of the material. In particular for degradable/absorbable materials, the degradation characteristics of the material and the resulting tissue response should be determined.

To find similar documents by classification:

11.020 (Medical sciences and health care facilities in general Including quality and environmental management in health care technology IT application in health care technology, see 35.240.80)

11.100.20 (Biological evaluation of medical devices Medical microbiology, see 07.100.10)


Active implantable medical devices. Medical devices. Directive 2007/47/EC of the European Parliament and of the council of 5 September 2007 amending Council Directive 90/385/EEC on the approximation of the laws of the Member States relating to active implantable medical devices, Council Directive 93/42/EEC concerning medical devices and Directive 98/8/EC concerning the placing of biocidal products on the market

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

ASTM-F88
Standard Test Method for Seal Strength of Flexible Barrier Materials

ASTM-F1980
Standard Guide for Accelerated Aging of Sterile Barrier Systems and Medical Devices

ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems

ORDER

Price:

$179.55        


Want this as a site license?



Designation Name

SS-EN ISO 10993-6:2017

Revision Level

2017 EDITION

Status

Current

Publication Date

Jan. 9, 2017

Language(s)

English

Page Count

48

International Equivalent

EN ISO 10993-6:2016(IDT); ISO 10993-6:2016(IDT)