This document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization which can include one or more of the following: the identification of its materials of construction (medical device configuration); the characterization of the materials of construction via the identification and quantification of their chemical constituents (material composition); the characterization of the medical device for chemical substances that were introduced during manufacturing (e.g. mould release agents, process contaminants, sterilization residues); the estimation (using laboratory extraction conditions) of the potential of the medical device, or its materials of construction, to release chemical substances under clinical use conditions (extractables); the measurement of chemical substances released from a medical device under its clinical conditions of use (leachables). This document can also be used for chemical characterization (e.g. the identification and/or quantification) of degradation products. Information on other aspects of degradation assessment are covered in ISO 10993-9, ISO 10993-13, ISO 10993-14 and ISO 10993-15. The ISO 10993 series is applicable when the material or medical device has direct or indirect body contact (see ISO 10993-1 for categorization by nature of body contact). This document is intended for suppliers of materials and manufacturers of medical devices, to support a biological evaluation.
To find similar documents by classification:
11.100.20 (Biological evaluation of medical devices Medical microbiology, see 07.100.10)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASTM-A480Standard Specification for General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip
ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems
UL-94
Standard for Tests for Flammability of Plastic Materials for Parts in Devices and Appliances
Designation Name
SS-EN ISO 10993-18:2020/A1:2023
Revision Level
2020 EDITION AMENDMENT 1
Status
Current
Publication Date
Aug. 11, 2023
Language(s)
English
Page Count
16
International Equivalent
EN ISO 10993-18:2020/A1:2023(IDT); ISO 10993-18:2020/Amd 1:2022(IDT)