SS-EN-12953-1 Shell boilers - Part 1: General

SS-EN-12953-1 - 2012 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


1.1 General This European Standard applies to shell boilers with volumes in excess of 2 litres for the generation of steam and/or hot water at a maximum allowable pressure greater than 0,5 bar and with a temperature in excess of 110 °C. The purpose of this European Standard is to ensure that the hazards associated with the operation of shell boilers are reduced to a minimum and that adequate protection is provided to contain the hazards that still prevail when the shell boiler is put into service. This protection will be achieved by the proper application of the design, manufacturing, testing and inspection methods and techniques incorporated in the various parts of this European Standard. Where appropriate, adequate warning of residual hazards and the potential for misuse are given in the training and operating instructions and local to the equipment concerned (see EN 12953-7 and EN 12953-8). It is the manufacturer's responsibility, in addition to complying with the requirements of this standard, to take into consideration special measures which could be necessary in order to achieve by manufacturing the required level of safety in accordance with the EU Directive 97/23/EC (PED). NOTE 1 Further requirements relating to operating instructions in prEN 12953-13 and to hazard analysis in CEN/TS 764-6 should be taken into consideration. This European Standard specifies requirements for both directly fired and electrically heated boilers including Low Pressure Boilers (LPB, see 3.6) as well as for heat recovery boilers with a gas-side pressure not exceeding 0,5 bar of cylindrical design, constructed from carbon or carbon manganese steels by fusion welding and a design pressure not exceeding 40 bar. The boilers covered by this European Standard are intended for land use for providing steam or hot water (typical examples are shown in Figures 1 to 6). For Low Pressure Boilers (LPB) less stringent requirements concerning design and calculation are acceptable. Details ar...

To find similar documents by classification:

27.060.30 (Boilers and heat exchangers Including steam pressure vessels Heat exchangers for medical use, see 11.040.10 Heat exchangers for the chemical industry, see 71.120.30 Heat exchangers for the petroleum and natural gas industry, see 75.180.20 Heating appliances for buildings, see 97.100)

27.100 (Power stations in general Including thermal power plants Nuclear power plants, see 27.120.20 Hydraulic power plants, see 27.140 Solar power stations, see 27.160 Wind turbine systems, see 27.180)


Pressure equipment

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

ORDER

Price:

$179.55        


Want this as a site license?



Designation Name

SS-EN 12953-1:2012

Revision Level

2012 EDITION

Status

Current

Publication Date

March 9, 2012

Language(s)

English

Page Count

44

International Equivalent

EN 12953-1:2012(IDT)