SIS-CEN-17286 Stationary source emissions - Mercury monitoring using sorbent traps

SIS-CEN-17286 - 2019 EDITION - CURRENT


Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


The purpose of this document is to establish performance benchmarks for, and to evaluate the acceptability of, sorbent trap monitoring systems used to monitor total vapour- phase mercury (Hg) emissions in stationary source flue gas streams. These monitoring systems involve continuous repetitive in-flue sampling using paired sorbent traps with subsequent analysis of the time-integrated samples. This document is suitable for both short-term (periodic) measurements and long-term (continuous) monitoring using sorbent traps. NOTE When this Technical Specification has been validated, the sorbent trap method will be an Alternative Method subject to the restrictions on applicability defined below. Until that time, EN 13211 is the only accepted Reference Method for both short-term (periodic) measurements and for calibrating continuous monitoring systems, including those with long-term sampling systems. EN 13211 is a wet chemistry approach that relies on absorption of mercury into impinger solutions. The substance measured according to this specification is the total vapour phase mercury in the flue gas, which represents the sum of the elemental mercury (Hg0) and gaseous forms of oxidized mercury (Hg2+), such as mercury (II) chloride, in mass concentration units of micrograms (µg) per dry meter cubed (m3). The analytical range is typically 0,1 to greater than 50 µg/m3. The sorbent tube approach is intended for use under relatively low particulate conditions (typically less than 100 mg/m3) when monitoring downstream of all pollution control devices, e.g. at coal fired power plants and cement plants. In this case, the contribution of mercury in the particulate fraction is considered to be negligible (typically less than 5 % of total mercury). However, it shall be noted that the sorbent trap does take account of the finest particle fraction that is sampled with the flue gas, in addition to capturing the vapour phase mercury. This specification also contains routine pro...

To find similar documents by classification:

13.040.40 (Stationary source emissions)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

ORDER

Price:

$219.75        


Want this as a site license?



Designation Name

SIS-CEN/TS 17286:2019

Revision Level

2019 EDITION

Status

Current

Publication Date

March 18, 2019

Language(s)

English

Page Count

72