ISO-5151 Non-ducted air conditioners and heat pumps - Testing and rating for performance

ISO-5151 - 3RD EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ISO standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Included in this current edition are the following subparts:

 3RD EDITION - July 1, 2017
 FOR 3RD EDITION AMENDMENT 1 SEE - Oct. 1, 2020

ISO 5151:2017 specifies performance testing, the standard conditions and the test methods for determining the capacity and efficiency ratings of air-cooled air conditioners and air-to-air heat pumps.

ISO 5151:2017 is applicable to the following equipment:

- non-ducted air-cooled air conditioners and non-ducted air-to-air heat pumps; or

- ducted air conditioners and/or ducted heat pumps rated at less than 8 kW and intended to operate at an external static pressure of less than 25 Pa.

ISO 5151:2017 is limited to:

- residential, commercial and industrial single-package and split-system air conditioners and heat pumps;

- factory-made, electrically driven and use mechanical compression;

- utilizing single, multiple and variable capacity components;

- multiple split-system utilizing one or more refrigeration systems, one outdoor unit and one or more indoor units, controlled by a single thermostat/controller.

The requirements of testing and rating contained in this document are based on the use of matched assemblies.

ISO 5151:2017 is not applicable to the rating and testing of the following:

a) water-source heat pumps or water cooled air conditioners;

b) multi-split-system air conditioners and air-to-air heat pumps (follow ISO 15042 for the testing of such equipment);

c) mobile (windowless) units having a condenser exhaust duct;

d) individual assemblies not constituting a complete refrigeration system;

e) equipment using the absorption refrigeration cycle;

f) ducted equipment except for those specified in this clause (follow ISO 13253 for the testing of such equipment).

ISO 5151:2017 does not cover the determination of seasonal efficiencies, which can be required in some countries because they provide a better indication of efficiency under actual operating conditions.

NOTE Throughout this document, the terms "equipment" and "systems" mean "air conditioners" and/or "heat pumps".

ORDER

Price:

$242.50        


Want this as a site license?

To find similar documents by classification:

23.120 (Ventilators. Fans. Air-conditioners Marine ventilation and air-conditioning systems, see 47.020.90 Mining ventilation and air-conditioning systems, see 73.100.20 Ventilation and air-conditioning in buildings, see 91.140.30)

27.080 (Heat pumps)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ISO 5151:2017

Revision Level

3RD EDITION

Status

Current

Publication Date

July 1, 2017

Committee Number

ISO/TC 86/SC 6