ISO-16494-1 › Heat recovery ventilators and energy recovery ventilators - Method of test for performance - Part 1: Development of metrics for evaluation of energy related performance
The following bibliographic material is provided to assist you with your purchasing decision:
Included in this current edition are the following subparts:
FOR 1ST EDITION AMENDMENT 1 SEE - Nov. 1, 2023
This document specifies a method of testing the ventilation and energy related performance of heat recovery ventilators (HRVs) and energy recovery ventilators (ERVs) that do not contain any supplemental heating (except for defrost), cooling, humidification, or dehumidification components.
Exchanger types of HRVs and ERVs are
a) fixed-plate exchangers (also known as recuperators),
b) rotary exchangers, including heat wheels and total energy wheels (also known as regenerators), and
c) heat pipe exchangers using a heat transfer medium, excluding those using mechanical pumping,
This document does not provide a method for measuring the response of exchangers to the formation of frost.
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ISO 16494-1:2022
Revision Level
1ST EDITION
Status
Current
Publication Date
June 1, 2022
Committee Number
ISO/TC 86/SC 6