ISO-10993-18 Biological evaluation of medical devices - Part 18: Chemical characterization of medical device materials within a risk management process

ISO-10993-18 - 2ND EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ISO standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Included in this current edition are the following subparts:

 2ND EDITION - Jan. 1, 2020
 FOR 2ND EDITION AMENDMENT 1 SEE - May 1, 2022

This document specifies a framework for the identification, and if necessary, quantification of constituents of a medical device, allowing the identification of biological hazards and the estimation and control of biological risks from material constituents, using a generally stepwise approach to the chemical characterization which can include one or more of the following:

— the identification of its materials of construction (medical device configuration);

— the characterization of the materials of construction via the identification and quantification of their chemical constituents (material composition);

— the characterization of the medical device for chemical substances that were introduced during manufacturing (e.g. mould release agents, process contaminants, sterilization residues);

— the estimation (using laboratory extraction conditions) of the potential of the medical device, or its materials of construction, to release chemical substances under clinical use conditions (extractables);

— the measurement of chemical substances released from a medical device under its clinical conditions of use (leachables).

This document can also be used for chemical characterization (e.g. the identification and/or quantification) of degradation products. Information on other aspects of degradation assessment are covered in ISO 10993-9, ISO 10993-13, ISO 10993-14 and ISO 10993-15.

The ISO 10993 series is applicable when the material or medical device has direct or indirect body contact (see ISO 10993-1 for categorization by nature of body contact).

This document is intended for suppliers of materials and manufacturers of medical devices, to support a biological evaluation.

ORDER

Price:

$242.50        


Want this as a site license?

To find similar documents by classification:

11.100.20 (Biological evaluation of medical devices Medical microbiology, see 07.100.10)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems

ASTM-F88
Standard Test Method for Seal Strength of Flexible Barrier Materials

ISO-10993-1
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process

Document Number

ISO 10993-18:2020

Revision Level

2ND EDITION

Status

Current

Publication Date

Jan. 1, 2020

Committee Number

ISO/TC 194