IEC-62209-2 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)

IEC-62209-2 - EDITION 1.1 - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:


IEC 62209-2:2010+A1:2019 is applicable to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments. For transmitters used in close proximity to the human ear, the procedures of IEC 62209-1:2005 are applicable. IEC 62209-2:2010 is applicable for radio frequency exposure in the frequency range of 30 MHz to 6 GHz, and may be used to measure simultaneous exposures from multiple radio sources used in close proximity to human body. Definitions and evaluation procedures are provided for the following general categories of device types:
- body-mounted,
- body-supported,
- desktop,
- front-of-face,
- hand-held,
- laptop,
- limb-mounted,
- multi-band,
- push-to-talk,
- clothing-integrated. The types of devices considered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers. IEC 62209-2:2010 gives guidelines for a reproducible and conservative measurement methodology for determining the compliance of wireless devices with the SAR limits. The contents of the corrigendum of June 2010 have been included in this copy. This consolidated version consists of the first edition (2010) and its amendment 1 (2019). Therefore, no need to order amendment in addition to this publication.

To find similar documents by classification:

33.050.10 (Telephone equipment)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IEC-60601-1
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance

AAMI/IEC-62366-1
Medical devices - Part 1: Application of usability engineering to medical devices

FDA-SHERMAN FOOD
Sherman Food, Drug, and Cosmetic Laws (California)

Document Number

IEC 62209-2 Ed. 1.1 b:2019

Revision Level

EDITION 1.1

Status

Superseded

Publication Date

May 1, 2019

Committee Number

106