ASTM-F773 Practice for Measuring Dose Rate Response of Linear Integrated Circuits

ASTM-F773 - ADOPT WITHDRAWN - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Practice for Measuring Dose Rate Response of Linear Integrated Circuits

Scope

1.1 This practice covers the measurement of the response of linear integrated circuits, under given operating conditions, to pulsed ionizing radiation. The response may be either transient or more lasting, such as latchup. The radiation source is either a flash X-ray machine (FXR) or an electron linear accelerator (LINAC).

1.2 The precision of the measurement depends on the homogeneity of the radiation field and on the precision of the radiation dosimetry and the recording instrumentation.

1.3 The test may be considered to be destructive either for further tests or for other purposes if the total radiation dose exceeds some predetermined level. Because this level depends both on the kind of integrated circuit and on the application, a specific value must be agreed upon by the parties to the test. (See 6.10.)

1.4 Setup, calibration, and test circuit evaluation procedures are included in this practice.

1.5 Procedures for lot qualification and sampling are not included in this practice.

1.6 Because response varies with different device types, the dose rate range for any specific test is not given in this practice but must be agreed upon by the parties to the test.

1.7 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statement is given in 7.9.2.

Keywords

Circuitry; Current measurement-semiconductors; Destructive testing-semiconductors; Dose rate threshold; Dosimetry; Electrical conductors-semiconductors; Electron linear accelerator; Flash x-ray machines (FXR); Integrated circuits; Ionizing radiation; Irradiance/irradiation-semiconductors; Lasers and laser applications; Linear threshold voltage; Radiation exposure-electronic components/devices; Total dose; Voltage; dose rate response of linear integrated circuits, practice; ICS Number Code 31.200 (Integrated circuits. Microelectronics)

To find similar documents by classification:

31.200 (Integrated circuits. Microelectronics Including electronic chips, logical and analogue microstructures Microprocessors, see 35.160)

To find similar documents by Federal Supply Class Code:

FSC 5962 (Microcircuits, Electronic)

 

Customers who bought this document also bought:

MIL-STD-883
Microcircuits

MIL-PRF-38535
Integrated Circuits (Microcircuits) Manufacturing, General Specification for

IPC/EIA-J-STD-002
Solderability Tests for Component Leads, Terminations, Lugs, Terminals and Wires

Document Number

ASTM-F773

Revision Level

ADOPT WITHDRAWN

Status

Superseded

Modification Type

Withdrawn

Publication Date

April 18, 2011

Document Type

Practice

Page Count

1 page

Committee Number

F01.11