ASTM-F1595 › Standard Practice for Viewing Conditions for Visual Inspection of Membrane Switches
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This practice covers procedures for performing visual inspection of membrane switches. This includes visual inspection of overlays and circuitry.
1.2 This practice defines lighting parameters, distance from eye to specimen, viewing angle, and the viewing time allowed for a specific size specimen.
1.3 This practice is only designed for visual inspection of aesthetic qualities of membrane switches. It is not intended for color matching or gloss measurement.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Significance and Use
This practice is designed to enable all manufacturers and users of membrane switches to perform visual inspections under uniform conditions. The aim is to eliminate key variables in the inspection procedures so specimens can be viewed more objectively.
Viewing specimens under these conditions could reveal cosmetic defects in the specimen. Many of these defects or flaws are due to variables in the raw materials or the manufacturing process. These cosmetic flaws or defects do not necessarily mean that the specimen is defective. The determination of whether a specimen is acceptable or defective varies with the application and the needs of the user. Therefore, customer and vendor must agree on acceptable quality standards prior to manufacturing.
This practice does not establish standards for acceptability of specimens, only how they must be viewed (inspected).
This practice is not intended to be used for color matching purposes. Color matching must be performed under more precise lighting conditions outside the scope of this practice.
Keywords
continuous scanning motion; footcandles; membrane switches; overlays; window areas; Foot-candles; Continuous scanning motion; Membrane switches; Overlay materials/applications; Visual examination--electronic components/devices; Window areas
To find similar documents by ASTM Volume:
10.04 (Electronics; Declarable Substances in Materials; 3D Imaging Systems)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASTM-D4169Standard Practice for Performance Testing of Shipping Containers and Systems
ISO-15223-1
Medical devices - Symbols to be used with information to be supplied by the manufacturer - Part 1: General requirements
UL-2900-2-1
Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems
Document Number
ASTM-F1595-00(2012)
Revision Level
2000 R12 EDITION
Status
Superseded
Modification Type
Reapproval
Publication Date
March 15, 2012
Document Type
Practice
Page Count
2 pages
Committee Number
F01.18