ASTM-F1208 › Standard Specification for Minimum Performance and Safety Requirements for Anesthesia Breathing Systems (Withdrawn 2014)
The following bibliographic material is provided to assist you with your purchasing decision:
This specification covers breathing systems and components employed with anesthesia gas machines for humans. This specification considers the circle system as a whole and some of its components individually. A particular emphasis is placed upon component arrangement in the circle absorber-type system, and submits a system of standard description and notation. The circle system is divided into four segments: segment 1 - from patient to expiratory valve, segment 2 - from expiratory valve to reservoir bag, segment 3 - from reservoir bag to inspiratory valve, and segment 4 - from inspiratory valve to patient. Leakage of breathing system and resistance of breathing system shall be tested to meet the requirements prescribed. The adjustable pressure-limiting valves, reservoir bag connectors and reservoir bags, carbon dioxide absorbers, unidirectional valves, and optional components shall meet the requirements prescribed.
Scope
1.1 This specification covers breathing systems and components employed with anesthesia gas machines for humans. This specification considers the circle system as a whole and some of its components individually. A particular emphasis is placed upon component arrangement in the circle absorber-type system, and submits a system of standard description and notation. Excluded are ventilators for use during anesthesia, Mapelson nonrebreathing type systems, as well as breathing systems and related components of dental analgesia machines. (For rationale, see Appendix X1.)
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.3 This specification is arranged as follows:
Keywords
anesthesia absorber assembly; anesthesia breathing systems; anesthesia breathing system components; ICS Number Code 11.040.10 (Anaesthetic, respiratory and reanimation equipment)
To find similar documents by ASTM Volume:
13.02 (Emergency Medical Services; Search and Rescue; Anesthetic and Respiratory Equipment)
To find similar documents by classification:
11.040.10 (Anaesthetic, respiratory and reanimation equipment Including medical gas installations)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ISO-5356-1Anaesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets
IEC-60601-1-2
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems
Document Number
ASTM-F1208-89(2005)
Revision Level
1989 R05 EDITION
Status
Cancelled
Modification Type
Withdrawn
Publication Date
May 1, 2005
Document Type
Specification
Page Count
13 pages
Committee Number
F29.10