ASTM-F1100 Standard Specification for Ventilators Intended for Use in Critical Care (Withdrawn 2004)

ASTM-F1100 - 1990 R97 EDITION - CANCELLED -- See the following: IEC-60601-2-12
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Specification for Ventilators Intended for Use in Critical Care (Withdrawn 2004)

Scope

1.1 General -This specification establishes minimum performance and safety requirements for all ventilators and ventilator circuits intended for use with adult, child, or infant patients in critical care within the hospital and introduced for sale after the acceptance date of this specification, except as noted below. Definitions, performance requirements, test methods, and rationale are included. Several definitions have been included in Section 3.1 and Appendix X1 that are not used in the text of this specification. This material has been included for the sake of completeness, and for any possible educational benefit that may be served.

1.2 Exclusions -This specification does not apply to body ventilators such as the tank ventilator or the chest cuirass nor does it apply to ventilators utilizing the Sanders technique or "jet" ventilation, (venturi effect type) high frequency ventilators (greater than 2.5 Hz), or anesthesia ventilators. This specification does not apply to ventilators intended for use in transport applications or home care, nor does it apply to those ventilators developed for veterinary applications. The application of critical care ventilators in the home environment is not covered by this specification nor is the hospital use of transport or home care ventilators. (See also Appendix X2.1.)

1.3 The following precautionary caveat pertains to the test methods portion only, Section 6, of this specification: This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

critical patient care; hospitals; patient care; performance-medical materials/applications; safety precautions-medical materials/applications; ventilators; ventilators for use in critical care; ICS Number Code 23.120 (Ventilators. Fans. Air-conditioners)

To find similar documents by ASTM Volume:

13.02 (Emergency Medical Services; Search and Rescue; Anesthetic and Respiratory Equipment)

To find similar documents by classification:

23.120 (Ventilators. Fans. Air-conditioners Marine ventilation and air-conditioning systems, see 47.020.90 Mining ventilation and air-conditioning systems, see 73.100.20 Ventilation and air-conditioning in buildings, see 91.140.30)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IPC-A-610
Acceptability of Electronic Assemblies (Hardcopy format)

ASTM-F1054
Standard Specification for Conical Fittings (Withdrawn 2005)

MIL-STD-883
Microcircuits

Document Number

ASTM-F1100-90(1997)

Revision Level

1990 R97 EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

May 18, 1990

Document Type

Specification

Page Count

13 pages

Committee Number

F29.14