ASTM-E986 › Standard Practice for Scanning Electron Microscope Beam Size Characterization
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This practice provides a reproducible means by which one aspect of the performance of a scanning electron microscope (SEM) may be characterized. The resolution of an SEM depends on many factors, some of which are electron beam voltage and current, lens aberrations, contrast in the specimen, and operator-instrument-material interaction. However, the resolution for any set of conditions is limited by the size of the electron beam. This size can be quantified through the measurement of an effective apparent edge sharpness for a number of materials, two of which are suggested. This practice requires an SEM with the capability to perform line-scan traces, for example, Y-deflection waveform generation, for the suggested materials. The range of SEM magnification at which this practice is of utility is from 1000 to 50 000 × . Higher magnifications may be attempted, but difficulty in making precise measurements can be expected.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Significance and Use
4.1 The traditional resolution test of the SEM requires, as a first step, a photomicrograph of a fine particulate sample taken at a high magnification. The operator is required to measure a distance on the photomicrograph between two adjacent, but separate edges. These edges are usually less than one millimetre apart. Their image quality is often less than optimum limited by the S/N ratio of a beam with such a small diameter and low current. Operator judgment is dependent on the individual acuity of the person making the measurement and can vary significantly.
4.2 Use of this practice results in SEM electron beam size characterization which is significantly more reproducible than the traditional resolution test using a fine particulate sample.
Keywords
electron beam size; E766; graphite fiber; magnification; NIST–SRM 2069B; resolution; SEM; SEM performance; spot size; waveform ;
To find similar documents by ASTM Volume:
03.01 (Metals -- Mechanical Testing; Elevated and Low-Temperature Tests; Metallography)
To find similar documents by classification:
31.120 (Electronic display devices Including liquid crystal displays)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASTM-E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM-B249
Standard Specification for General Requirements for Wrought Copper and Copper-Alloy Rod, Bar, Shapes and Forgings
ASTM-B283
Standard Specification for Copper and Copper-Alloy Die Forgings (Hot-Pressed)
Document Number
ASTM-E986-04(2017)
Revision Level
2004 R17 EDITION
Status
Current
Modification Type
Reapproval
Publication Date
June 15, 2017
Document Type
Practice
Page Count
3 pages
Committee Number
E04.11