ASTM-E981 Standard Test Method for Estimating Sensory Irritancy of Airborne Chemicals

ASTM-E981 - 2019 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Estimating Sensory Irritancy of Airborne Chemicals
ORDER

Price:

$76.00        


Want this as a site license?

Changes from the previous issue

A redline edition is available for this document, with all changes visible. Ask Document Center Inc. for more information.

Scope

1.1 This laboratory test method provides a rapid means of determining sensory irritant potential of airborne chemicals or mixtures. It may also be used to estimate threshold limit values (TLV) for man. However, it cannot be used to evaluate the relative obnoxiousness of odors.

1.2 This test method is intended as a supplement to, not a replacement for, chronic inhalation studies used to establish allowable human tolerance levels.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific hazard information is given in Section 6.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

3.1 This test method was developed to meet the following criteria:

3.1.1 It provides positive recognition of sensory irritants of widely varying potencies.

3.1.2 It is sufficiently simple to permit the testing of large numbers of materials.

3.1.3 This test method is capable of generating concentration-response curves for purposes of compound comparison.

3.1.4 This test method has good reproducibility.

3.2 This test method can be used for a variety of divergent purposes, including the assessment of comparative irritancy of compounds or formulations and setting interim exposure levels for the workplace (1, 2).2

3.3 It has been shown that for a wide variety of chemicals and mixtures, a perfect rank order correlation exists between the decreases in respiratory rate in mice and subjective reports of sensory irritation in man (1, 3, 4, 5).

3.4 A quantitative estimate of the sensory irritancy of a wide variety of materials can be obtained from concentration-response curves developed using this method (1, 3, 4, 6, 7, 8, 9).

3.5 Although this test method is intended to measure sensory irritation of the nasal mucosa, the cornea is innervated by the same nerve. This animal model will, therefore, allow an estimate of the irritant potential of cosmetic ingredients or other household products to the eye, assuming that they can be aerosolized (10).

3.6 This test method is recommended for setting interim guidelines for exposure of humans to chemicals in the workplace, to assess acute sensory irritation resulting from inadvertent spills of household products, and to assess the comparative irritancy of formulations or materials intended for a variety of uses (see Appendix X2).

FIG. 1 Typical Tracing of Normal Mouse Respiration (Top), and of a“ Moderate” Sensory Irritant Response (Bottom)

Typical Tracing of Normal Mouse Respiration (Top),
 and of a“ Moderate” Sensory Irritant Response (Bottom)Typical Tracing of Normal Mouse Respiration (Top),
 and of a“ Moderate” Sensory Irritant Response (Bottom)

Note 1: Taken from Ref. (3).

FIG. 2 Typical Tracing of Normal Mouse Respiration (Top), a Moderate Pulmonary Irritant Response (Center), and an Extreme Pulmonary Irritant Response (Bottom)

Typical Tracing of Normal Mouse Respiration (Top),
 a Moderate Pulmonary Irritant Response (Center), and an Extreme Pulmonary
 Irritant Response (Bottom)Typical Tracing of Normal Mouse Respiration (Top),
 a Moderate Pulmonary Irritant Response (Center), and an Extreme Pulmonary
 Irritant Response (Bottom)

Note 1: Taken from Ref. (8).

3.7 This test method will detect irritating effects at concentrations far below those at which pathological changes are observed (9).

Note 1: A good overview of the toxicological evaluation of irritant compounds is given in Ref (8).

Keywords

airborne; chemicals; inhalation; mice; respiration; sensory irritancy;; ICS Number Code 13.040.01 (Air quality in general)

To find similar documents by ASTM Volume:

11.06 (Biological Effects and Environmental Fate; Biotechnology)

To find similar documents by classification:

13.040.01 (Air quality in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E981-19

Revision Level

2019 EDITION

Status

Current

Modification Type

Revision

Publication Date

March 11, 2019

Document Type

Test Method

Page Count

12 pages

Committee Number

E50.47