ASTM-E816 Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers

ASTM-E816 - 2015 R23 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Calibration of Pyrheliometers by Comparison to Reference Pyrheliometers
ORDER

Price:

$76.00        


Want this as a site license?

Scope

1.1 This test method has been harmonized with, and is technically equivalent to, ISO 9059.

1.2 Two types of calibrations are covered by this test method. One is the calibration of a secondary reference pyrheliometer using an absolute cavity pyrheliometer as the primary standard pyrheliometer, and the other is the transfer of calibration from a secondary reference to one or more field pyrheliometers. This test method proscribes the calibration procedures and the calibration hierarchy, or traceability, for transfer of the calibrations.

Note 1-It is not uncommon, and is indeed desirable, for both the reference and field pyrheliometers to be of the same manufacturer and model designation.

1.3 This test method is relevant primarily for the calibration of reference pyrheliometers with field angles of 5 to 6°, using as the primary reference instrument a self-calibrating absolute cavity pyrheliometer having field angles of about 5°. Pyrheliometers with field angles greater than 6.5° shall not be designated as reference pyrheliometers.

1.4 When this test method is used to transfer calibration to field pyrheliometers having field angles both less than 5° or greater than 6.5°, it will be necessary to employ the procedure defined by Angstrom and Rodhe.

1.5 This test method requires that the spectral response of the absolute cavity chosen as the primary standard pyrheliometer be nonselective over the range from 0.3 to 10-[mu]m wavelength. Both reference and field pyrheliometers covered by this test method shall be nonselective over a range from 0.3 to 4-[mu]m wavelength.

1.6 The primary and secondary reference pyrheliometers shall not be field instruments and their exposure to sunlight shall be limited to calibration or intercomparisons. These reference instruments shall be stored in an isolated cabinet or room equipped with standard laboratory temperature and humidity control.

Note 2-At a laboratory where calibrations are performed regularly, it is advisable to maintain a group of two or three secondary reference pyrheliometers that are included in every calibration. These serve as controls to detect any instability or irregularity in the standard reference pyrheliometer.

1.7 This test method is applicable to calibration procedures using natural sunshine only.

Keywords

alibration-nuclear analysis instrumentation; pyrheliometers-calibration, by comparison to reference pyrheliometers,; spec., ; Pyrheliometers; pyrheliometers-calibration, by comparison to reference pyrheliometers,; spec., ; Solar energy; pyrheliometers-calibration, by comparison to reference pyrheliometers,; spec., ;Order Form

To find similar documents by ASTM Volume:

14.04 (Laboratory Apparatus; Degradation of Materials; SI; Oxygen Fire Safety)

To find similar documents by classification:

27.160 (Solar energy engineering Including photovoltaic energy systems)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

MIL-C-24707/5
Castings, Ductile Iron and Austenitic Ductile Iron

MIL-STD-278
Welding and Casting Standard (Replacement Document Navsea Tech Pub S9074-AR-GIB-010/278)

AS-9000
Aerospace Basic Quality System Standard (Cancelled Feb 2004, Superseded by AS9100)

Document Number

ASTM-E0816-15R23

Revision Level

2015 R23 EDITION

Status

Current

Modification Type

Revision with Title Change

Publication Date

March 22, 2023

Document Type

Test Method

Page Count

11 pages

Committee Number

G03.09