ASTM-E3142 Standard Test Method for Thermal Lag of Thermal Analysis Apparatus

ASTM-E3142 - 2018A R23 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Thermal Lag of Thermal Analysis Apparatus
ORDER

Price:

$61.00        


Want this as a site license?

Scope

1.1 This test method addresses the dependence of temperature calibration on the temperature rate-of-change. This test method describes the determination of the thermal lag of thermal analysis apparatus and its application to the modification of the temperature calibration for that apparatus obtained at alternative linear temperature rates-of-change.

1.2 This test method is applicable, but not limited to, the temperature calibration of differential thermal analyzers (DTAs), differential scanning calorimeters (DSCs), thermogravimetric analyzers (TGAs), thermomechanical analyzers (TMAs), and dynamic mechanical analyzers (DMAs).

1.3 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 Differing temperature rates-of-change may be required for different measurements (for example, Test Method E698). Temperature calibration changes as a function of temperature rate-of-change. The use of the known thermal lag of an apparatus may be used to adjust the temperature calibration of the apparatus obtained at one temperature rate-of-change with that at another required for a given applications. This adjustment procedure for temperature calibration is described in 8.1.

5.2 This test method may be used in research, quality assurance, and specification acceptance.

Keywords

calibration; differential scanning calorimetry; differential thermal analysis; dynamic mechanical analysis; temperature calibration; thermal lag; thermogravimetric analysis; thermomechanical analysis;; ICS Number Code 17.200.20 (Temperature-measuring instruments)

To find similar documents by ASTM Volume:

14.01 (Healthcare Informatics)

To find similar documents by classification:

17.200.20 (Temperature-measuring instruments Including thermostats Medical thermometers, see 11.040.55)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E3142-18AR23

Revision Level

2018A R23 EDITION

Status

Current

Modification Type

New

Publication Date

July 5, 2023

Document Type

Test Method

Page Count

4 pages

Committee Number

E37.10