ASTM-E2851 Standard Specification for Ruggedness Requirements for HAZMAT Instrumentation

ASTM-E2851 - 2013 R21 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification establishes the ruggedness requirements for equipment used in Hazardous Material (HAZMAT) instrumentation, including devices used to detect or monitor for hazardous material. It defines for design and test purposes the environment in which HAZMAT equipment will likely be exposed during storage, transport, and field use. Passive personal protective equipment such as respirators and protective suits are not covered. The specification addresses materials and manufacture, physical and mechanical properties, performance and environmental requirements, dimensions, mass and permissible variations, workmanship, and finish and appearance. Definitions of terms specific to this standard are provided, including body-worn, hand-carried, mobile, portable, and transportable.

ORDER

Price:

$69.00        


Want this as a site license?

Scope

1.1 This specification describes the ruggedness requirements for equipment used during Hazardous Material (HAZMAT) operations. The conditions defined by this specification include those related to equipment storage, transport, and field use.

1.2 This specification does not address passive personal protective equipment (PPE) such as respirators and protective suits.

1.3 The equipment addressed by this specification includes devices used to detect or monitor for hazardous material.

1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. When using a HAZMAT instrument, follow the manufacturer’s guidance and appropriate safety practices for the threat expected or suspected in the environment where the instrument will be used.

Keywords

body-worn; hand-carried; HAZMAT; installed; instrumentation; mobile; portable; ruggedness; transportable

To find similar documents by ASTM Volume:

15.08 (Sensory Evaluation; Vacuum Cleaners; Security Systems and Equipment; Detention and Correctional Facilities; Homeland Security Applications)

To find similar documents by classification:

13.300 (Protection against dangerous goods Including performance requirements for dangerous goods, their handling, storage, transportation, marking, labelling, etc. Nuclear fissile materials, see 27.120.30 Explosives, see 71.100.30)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E2851_E2851M-13R21

Revision Level

2013 R21 EDITION

Status

Current

Modification Type

New

Publication Date

Dec. 22, 2021

Document Type

Specification

Page Count

5 pages

Committee Number

E54.01