ASTM-E2593 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers

ASTM-E2593 - 2017 R23 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers
ORDER

Price:

$76.00        


Want this as a site license?

Scope

1.1 This guide describes the techniques and apparatus required for the accuracy verification of industrial platinum resistance thermometers constructed in accordance with Specification E 1137/E 1137M and the evaluation of calibration uncertainties. The procedures described apply over the range of 200 °C to 650 °C.

1.2 This guide is not intended to describe the procedures necessary for the calibration of platinum resistance thermometers intended to be used as calibration standards or Standard Platinum Resistance Thermometers. Consequently, calibration of these types of instruments is outside the scope of this guide.

1.3 Industrial platinum resistance thermometers are available in many styles and configurations. This guide does not purport to determine the suitability of any particular design, style, or configuration for calibration over a desired temperature range.

1.4 The evaluation of uncertainties is based upon current international practices as described in ISO/TAG 4/WG 3 Guide to the Evaluation of Uncertainty in Measurement and ANSI/NCSL Z540-2-1997 U.S. Guide to the Expression of Uncertainty in Measurement.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This guide is intended to be used by laboratories interested in the calibration of industrial platinum resistance thermometers that are intended to satisfy the requirements of Specification E 1137/E 1137M. It is intended to provide a consistent method for calibration and uncertainty evaluation while still allowing the user some flexibility in choice of apparatus and instrumentation. It is understood that the limits of uncertainty obtained depend in a large part upon the apparatus and instrumentation used. Therefore, since this guide is not prescriptive in approach, it provides detailed instruction in uncertainty evaluation to accommodate the variety of apparatus and instrumentation that may be employed.

This guide is intended primarily to satisfy applications requiring compliance to Specification E 1137/E 1137M. However, the techniques described may be appropriate in applications where higher accuracy calibrations are needed.

Keywords

ccuracy verification; calibration; industrial platinum resistance thermometer; platinum resistance thermometer; standard platinum resistance thermometer; uncertainty; ICS Number Code 17.200.20 (Temperature-measuring instruments)

To find similar documents by ASTM Volume:

14.03 (Temperature Measurement)

To find similar documents by classification:

17.200.20 (Temperature-measuring instruments Including thermostats Medical thermometers, see 11.040.55)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

NAS-410
NAS Certification and Qualification of Nondestructive Test Personnel

AWS-D17.1/D17.1M
Specification for Fusion Welding for Aerospace Applications

MIL-H-7199
Heat Treatment of Wrought Copper-Beryllium Alloys, Process for (Copper Alloys: Numbers C17000, C17200, C17300, C17500, and C17510) (Superseded by SAE-AMS-H-7199)

Document Number

ASTM-E2593-17R23

Revision Level

2017 R23 EDITION

Status

Current

Modification Type

New

Publication Date

July 10, 2023

Document Type

Guide

Page Count

15 pages

Committee Number

E20.03