ASTM-E1263 Standard Guide for Conduct of Micronucleus Assays in Mammalian Bone Marrow Erythrocytes (Withdrawn 2015)

ASTM-E1263 - 1997 R08 EDITION - CANCELLED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Conduct of Micronucleus Assays in Mammalian Bone Marrow Erythrocytes (Withdrawn 2015)

Scope

1.1 This guide provides recommended guidelines for performing the mammalian in vivo bone marrow micronucleus assay. Under appropriate test conditions, measurement of the frequency of newly formed micronucleated erythrocytes in bone marrow provides a convenient index of chromosomal damage in nucleated erythrocyte precursor cells. The rationale for the occurrence of micronuclei in conjunction with chromosomal damage has been described previously (1). This guide describes conditions under which the frequency of micronucleated erythrocytes in mammalian bone marrow is an appropriate measure of in vivo chromosomal damage, and provides guidelines for the design and technical execution of assays employing this endpoint.

1.2 The following guidelines for mammalian bone marrow erythrocyte micronucleus assays have been published by organizations concerned with the evaluation of genotoxicity test data. These references should be consulted for recommendations on details not covered in depth by this guide and for requirements of specific organizations or government agencies (2-6).

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This guide provides guidelines for the selection of animal species, dosage and sampling conditions, sampling and scoring methods, statistical design, and analysis of genotoxicity assays in which the endpoint measured is the frequency of micronucleated erythrocytes in mammalian bone marrow.

Keywords

Assay; Bone marrow nucleus assay; Chromosomal/genetic effects; Data analysis--environmental; Environmental control/fate; Environmental sampling/testing; Genetic examination; Mammalian in vivo bone marrow nucleus assay; Micronucleus assay; Statistical methods; Test animals; ICS Number Code 11.220 (Veterinary medicine)

To find similar documents by ASTM Volume:

13.01 (Medical and Surgical Materials and Devices)

To find similar documents by classification:

11.220 (Veterinary medicine Including equipment specific to veterinary medicine)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1263-97(2008)

Revision Level

1997 R08 EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

Aug. 1, 2008

Document Type

Guide

Page Count

7 pages

Committee Number

F04.16