Scope

1.1 This test method covers the determination of water from 0 % to 2.0 % mass in most liquid organic chemicals, with Karl Fischer reagent, using an automated coulometric titration procedure. Use of this test method is not applicable for liquefied gas products such as Liquid Petroleum Gas (LPG), Butane, Propane, Liquid Natural Gas (LNG), etc.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 Review the current Safety Data Sheets (SDS) for detailed information concerning toxicity, first-aid procedures, handling, and safety precautions.

1.4 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 8.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

4.1 The coulometric technique is especially suited for determining low concentrations of water in organic liquids that would yield small titers by the Karl Fischer volumetric procedure. The precision and accuracy of the coulometric technique decreases for concentrations of water much greater than 2.0 % because of the difficulty in measuring the small size of sample required. The test method assumes 100 % efficiency of coulombs in iodine production. Provision is made for verifying this efficiency. (See Table 1 and Note 5.)

Keywords

coulometric; Karl Fischer; organic liquids; pyridine-free; water;

To find similar documents by ASTM Volume:

06.04 (Paint -- Solvents; Aromatic Hydrocarbons)

15.05 (Engine Coolants; Halogenated Organic Solvents and Fire Extinguishing Agents; Industrial and Specialty Chemicals)

To find similar documents by classification:

71.080.01 (Organic chemicals in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

21CFR(800-1299)
Food and Drugs

21CFR(1-99)
Food and Drugs

ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems

Document Number

ASTM-E1064-24

Revision Level

2024 EDITION

Status

Current

Modification Type

Revision

Publication Date

Jan. 12, 2024

Document Type

Test Method

Page Count

5 pages

Committee Number

D16.04