ASTM-D7677 Standard Test Method for the Continuous Measurement of Dissolved Ozone in Low Conductivity Water

ASTM-D7677 - 2016 R23 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for the Continuous Measurement of Dissolved Ozone in Low Conductivity Water
ORDER

Price:

$69.00        


Want this as a site license?

Scope

1.1 This test method covers the on-line and in-line determination of dissolved ozone (DO3) in low conductivity water in the range from 0.001 mg/L to 5.0 mg/L DO3 and conductivity < 100 μS/cm, typical of pharmaceutical and microelectronics pure waters. DO3 is detected by correlating the response of a membrane-covered electrochemical sensor to the dissolved ozone concentration.

1.2 This test method provides a more convenient means for continuous measurement than the colorimetric methods typically used for grab sample measurements.

1.3 This test method has the advantage of high sensitivity as well as durability in the process environment and has few interferences.

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Dissolved Ozone is useful in many industries for water sanitization, TOC reduction, food preservation, cleaning-in-place of food and beverage systems, and pyrogen destruction. It is often necessary to know how much ozone has entered the water, how much remains, and the degree to which it has been removed before process use.

Some applications require that contact time, DO3 concentration integrated over time, be calculated, to assure disinfection.

Continuous observation of trends in these measurements are needed for continuous quality monitoring and the measurement may be used for closed loop control of ozonation.

In many pure water applications and especially where water quality is regulated by the FDA or similar enforcement agencies, ozone removal must be complete before the water is used. This test method is useful for detecting and determining dissolved ozone levels in water at the trace level as well as at process concentrations where sanitization and chemical reactions occur.

Keywords

Ozone; sanitization; dissolved gas; high purity water; pharmaceutical water; ICS Number Code 17.120.01 (Measurement of fluid flow in general)

To find similar documents by ASTM Volume:

11.01 (Water (I))

To find similar documents by classification:

17.120.01 (Measurement of fluid flow in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D7677-16R23

Revision Level

2016 R23 EDITION

Status

Current

Modification Type

New

Publication Date

Dec. 1, 2023

Document Type

Test Method

Page Count

5 pages

Committee Number

D19.03