ASTM-D7282 Standard Practice for Setup, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements

ASTM-D7282 - 2024 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Setup, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements
ORDER

Price:

$99.00        


Want this as a site license?

Scope

1.1 This practice covers consensus criteria for the setup, calibration, and quality control of nuclear instruments. Setup establishes the operating parameters of the instrument—for example, voltage or discriminator settings. Calibrations determine the instrument’s response characteristics—for example, its counting efficiency or energy response. Quality control ensures that the performance of the instrument remains acceptable for its intended use and consistent with the performance at the time of calibration.

1.2 This practice addresses four of the most commonly used types of nuclear counting instruments: alpha-particle spectrometer, gamma-ray spectrometer, gas proportional counter, and liquid scintillation counter.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions that are provided for information only and are not considered standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 This practice is consistent with a performance-based approach wherein the frequency of recalibration and instrument testing is linked to the results from continuing instrument quality control. Under the premise of this practice, a laboratory demonstrates that its instrument performance is acceptable for analyzing sample test sources.

5.2 When a laboratory demonstrates acceptable performance based on continuing instrument quality control data (that is, control charts and tolerance charts), batch QC samples (that is, blanks, laboratory control samples, replicates, matrix spikes, and other batch QC samples as may be applicable) and independent reference materials, traditional schedule-driven instrument recalibration is permissible but unnecessary.

5.3 When continuing instrument QC, batch QC, or independent reference material sample results indicate that instrument response has exceeded established control or tolerance limits, instrument calibration is required. Other actions related to sample analyses on the affected instruments may be required by the QMS.

5.4 The data obtained while following this practice will likely be stored electronically. The data remain in electronic storage, where they are readily available to produce plots, graphs, spreadsheets, and other types of displays and reports. The QMS should specify the frequency and performance of data storage backup.

Keywords

activity; alpha; beta; calibration; control chart; gamma; gas proportional; liquid scintillation; measurements; quality control; spectrometry;

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IEC-60846-1
Radiation protection instrumentation - Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation - Part 1: Portable workplace and environmental meters and monitors

ASTM-F1158
Standard Guide for Inspection and Evaluation of Tampering of Security Seals

Document Number

ASTM-D7282-24

Revision Level

2024 EDITION

Status

Current

Modification Type

Revision

Publication Date

May 13, 2024

Document Type

Practice

Page Count

26 pages

Committee Number

D19.04