ASTM-D7198 Standard Specification for Disposable Embalming Gloves for Single-Use Applications

ASTM-D7198 - 2005 R23 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification covers certain requirements for natural rubber (Latex), synthetic rubber (Polychloroprene and Nitrile), and vinyl (PVC) disposable gloves for use in conducting single-use embalming procedures. This specification covers natural rubber (Latex), synthetic rubber (Polychloroprene and Nitrile), and Vinyl (PVC) disposable gloves that fit either hand, paired gloves, gloves by size, and gloves packed in bulk. An assessment to measure the chemical resistance performance of the glove can be made based on the ultimate permeation (breakthrough) of embalming chemicals through the glove material over a specified period of time. The chemical permeation tests described in this specification are intended to be "Type Tests" for these types of gloves. The material shall conform to the required quality performances, which include freedom from holes, width, length, thickness, physical properties before aging and after accelerated aging, powder amount, and permeation. Latex shall be tested for protein content and antigenic protein content.

ORDER

Price:

$69.00        


Want this as a site license?

Scope

1.1 This specification covers certain requirements for natural rubber (Latex), synthetic rubber (Polychloroprene and Nitrile), and vinyl (PVC) disposable gloves for use in conducting single-use embalming procedures.

1.2 This specification covers natural rubber (Latex), synthetic rubber (Polychloroprene and Nitrile), and Vinyl (PVC) disposable gloves that fit either hand, paired gloves, gloves by size, and gloves packed in bulk.

1.3 An assessment to measure the chemical resistance performance of the glove can be made based on the ultimate permeation (breakthrough) of embalming chemicals through the glove material over a specified period of time.

1.4 This specification is similar to the following specifications: D 3578, D 4679, D 5250, D 6319, and D 6977.

1.5 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

disposable; embalming; gloves; latex; natural rubber; nitrile; polychloroprene; single-use; synthetic rubber; vinyl; ICS Number Code 11.140 (Hospital equipment)

To find similar documents by ASTM Volume:

09.02 (Rubber Products, Industrial - Specifications and Related Test Methods; Gaskets; Tires)

To find similar documents by classification:

11.140 (Hospital equipment Including hospital beds, surgical tables, medical garments, medical gloves, containers for sharp disposal, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D7198-05R23

Revision Level

2005 R23 EDITION

Status

Current

Modification Type

New

Publication Date

June 8, 2023

Document Type

Specification

Page Count

6 pages

Committee Number

D11.40