ASTM-D7013 › Standard Guide for Calibration Facility Setup for Nuclear Surface Gauges
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This guide outlines procedures for setup of nuclear moisture density gauge in shielded, Method A, and unshielded, Method B, configurations.
1.2 This guide does not attempt to describe the calibration techniques or methods. It is assumed that this guide will be used by persons familiar with the operations of the gauge and in performing proper calibration, service and maintenance.
1.3 This guide does not attempt to address maintenance or service procedures related to the gauge.
This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this guide to establish appropriate safety, and health practices and determine the applicability of regulatory limitations prior to use.
1.4 This guide offers an organized collection of information or a series of options and does not recommend a specific course of action. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of this guide may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without consideration of a projects many unique aspects. The word "Standard" in the title of this document has been approved through ASTM consensus process.
1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in practice D 6026.
1.5.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in the design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.
Significance and Use
Gauge calibration is conducted for the following purposes:
5.1.1 To ensure gauge measurement repeatability between gauges
5.1.2 To correct for electronic and mechanical changes over time
5.1.3 To adjust readings after major service to the gauge
To establish a proper calibration area for gauges
To reduce the chance of improper calibration
Note 1—The quality of the results produced by this standard is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of practice D 3740
Keywords
Gauge; nuclear gauge; calibration; calibration block; calibration reference block; ICS Number Code 27.120.10 (Reactor engineering)
To find similar documents by ASTM Volume:
04.09 (Soil and Rock (II): D5877 - latest)
To find similar documents by classification:
27.120.10 (Reactor engineering)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D7013_D7013M-23
Revision Level
2023 EDITION
Status
Current
Modification Type
New
Publication Date
March 22, 2023
Document Type
Guide
Page Count
6 pages
Committee Number
D18.08