ASTM-D5014 › Standard Test Method for Measurement of Formaldehyde in Indoor Air (Passive Sampler Methodology) (Withdrawn 2006)
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method covers personal or area measurements of formaldehyde in indoor air in the range from 0.01 to 17 mg/m (0.008 to 14 ppm v/v). Formaldehyde is collected in a passive diffusion sampler, and analyzed by a colorimetric method using 3-methyl-2-benzothiazolinone hydrazone hydrochloride (MBTH). The recommended sampling time is 15 min to 24 h.
1.2 The lower quantification limit of the MBTH test method is 0.03 [mu]g of formaldehyde per millilitre of absorbing solution used. A formaldehyde concentration of 0.01 mg/m (0.008 ppm v/v) can be determined in indoor air, based on using an aliquot of 5 mL of absorbing solution in the prescribed sampler for a period of 24 h and observing a minimum difference of 0.05 absorbance units from the blank when using spectrophotometer cells of path length 1 cm.
1.3 Water soluble aliphatic aldehydes give a significant positive interference (1, 2) nearly equal to formaldehyde on a molar basis. Further information on estimating potential and actual interferences from aliphatic aldehydes may be found in 6.2 and 10.1.7. Most other compounds which react to produce colored products are not gaseous or water soluble and, consequently, should not interfere.
1.4 The values stated in SI units are to be regarded as the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Notes 1 and 2.
Keywords
Atmospheric analysis-indoor; Colorimetric analysis-atmospheric; Diffusional sampling; Field testing-atmospheric analysis; Formaldehyde; Passive sampler methodology; measurement of formaldehyde in indoor air, passive sampler methodology,; test,; Building constructions/materials-decks; flammability-marine surface finishes (under controlled laboratory; conditions), test; ICS Number Code 13.040.01 (Air quality in general)
To find similar documents by ASTM Volume:
To find similar documents by classification:
13.040.01 (Air quality in general)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D5014-94(2000)e1
Revision Level
1994 R00(E1) EDITION
Status
Cancelled
Modification Type
Withdrawn
Publication Date
March 1, 2000
Document Type
Test Method
Page Count
6 pages
Committee Number
D22.05