ASTM-D3418 › Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method covers determination of transition temperatures and enthalpies of fusion and crystallization of polymers by differential scanning calorimetry.
Note 1: True heats of fusion are to be determined in conjunction with structure investigation, and frequently, specialized crystallization techniques are needed.
1.2 This test method is applicable to polymers in granular form or to any fabricated shape from which it is possible to cut appropriate specimens.
1.3 The normal operating temperature range is from the cryogenic region to 600°C. Certain equipment allows the temperature range to be extended.
1.4 The values stated in SI units are the standard.
Note 2: This test method does not apply to all types of polymers as written (see 6.8).
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
Note 3: This standard is similar but not equivalent to ISO 11357-1, -2, -3. The ISO procedures provide additional information not supplied by this test method.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Significance and Use
5.1 Thermal analysis provides a rapid method for measuring transitions due to morphological or chemical changes in a polymer as it is heated/cooled at a controlled rate through a specified temperature range. Change in specific heat capacity, heat flow and temperature values are determined for these transitions. Differential scanning calorimetry is used to assist in identifying specific polymers, polymer alloys, and certain polymer additives, which exhibit thermal transitions. Chemical reactions that cause or affect certain transitions have been measured with the aid of this technique; such reactions include oxidation, curing of thermosetting resins, and thermal decomposition.
5.2 This test method is useful for specification acceptance, process control, and research.
Keywords
crystallization; crystallization temperature; differential scanning calorimetry (DSC); enthalpy; first-order transition; glass transition; heat of crystallization; heat of fusion; heat of transition; melting; melting temperature; polymer; transition temperature;
To find similar documents by ASTM Volume:
08.02 (Plastics (II): D3222 - D5083)
To find similar documents by classification:
83.080.01 (Plastics in general)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASTM-D638Standard Test Method for Tensile Properties of Plastics
ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems
ISO-9001
Quality management systems - Requirements
Document Number
ASTM-D3418-21
Revision Level
2021 EDITION
Status
Current
Modification Type
Revision
Publication Date
Sept. 17, 2021
Document Type
Test Method
Page Count
8 pages
Committee Number
D20.30