ASTM-D3347 Standard Test Method for Flow Rate and Tap Density of Electrical Grade Magnesium Oxide For Use in Sheathed Heating Elements (Withdrawn 2002)

ASTM-D3347 - 1994 EDITION - CANCELLED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Flow Rate and Tap Density of Electrical Grade Magnesium Oxide For Use in Sheathed Heating Elements (Withdrawn 2002)

Scope

1.1 This test method covers the determination of the flow rate and the tap density which predicts the fill rate and flow rate of granular electrical grade magnesium oxide used in the manufacturing of sheathed heating elements.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Fill rate/density; Flow and flow rate-insulations; Magnesium oxide (electrical grade); Sheathed heating elements; Tap density; flow rate/tap density-electrical-grade MgO, for sheathed heating; elements, test; ICS Number Code 71.060.20 (Oxides)

To find similar documents by ASTM Volume:

10.02 (Electrical Insulation (II): D2518 - latest)

To find similar documents by classification:

71.060.20 (Oxides Including dioxides, peroxides, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D3347-94

Revision Level

1994 EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

June 15, 1994

Document Type

Test Method

Page Count

4 pages

Committee Number

D09.14