ASTM-D3299 › Historical Revision Information
Filament-Wound Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant Tanks, Standard
The following bibliographic material is provided to assist you with your purchasing decision:
This specification covers cylindrical corrosion-resistant tanks made of commercial-grade glass-fiber-reinforced polyester or vinylester thermoset resin fabricated by filament winding for above-ground vertical installation, to contain aggressive chemicals at atmospheric pressure as classified herein. This specification does not address the design of vessels intended for pressure above atmospheric, vacuum conditions, except as classified herein, or vessels intended for use with liquids heated above their flash points. Included are requirements for materials, properties, design, construction, dimensions, tolerances, workmanship, and appearance.
Scope
1.1 This specification covers cylindrical tanks fabricated by filament winding for above-ground vertical installation, to contain aggressive chemicals at atmospheric pressure as classified herein, and made of a commercial-grade polyester or vinylester resin. Included are requirements for materials, properties, design, construction, dimensions, tolerances, workmanship, and appearance.
1.2 This specification does not cover the design of vessels intended for pressure above atmospheric, vacuum conditions, except as classified herein, or vessels intended for use with liquids heated above their flash points.
1.3 The values given in parentheses are provided for information purposes only.
Note 1-Special design consideration should be given to vessels subject to superimposed mechanical forces, such as earthquakes, wind load, or agitation, and to vessels subject to service temperature in excess of 180°F (82°C), and to vessels with unsupported bottoms. Note 2-There is no similar or equivalent ISO standard.1.4 The following safety hazards caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
above ground; atmospheric; filament wound; polyester; tank; vinylester; ICS Number Code 23.020.10 (Stationary containers and tanks)
To find similar documents by ASTM Volume:
To find similar documents by classification:
23.020.10 (Stationary containers and tanks)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-D3299-00
Revision Level
2000 EDITION
Status
Superseded
Publication Date
March 10, 2000
Document Type
Specification
Page Count
16 pages
Committee Number
D20.23