Standard Test Method for Automated Separation and Collection of Particulate and Acidic Gaseous Fluoride in the Atmosphere (Double Paper Tape Sampler Method)
ORDER

Price:

$69.00        


Want this as a site license?

Scope

1.1 This test method describes the automatic separation and collection on chemically treated paper tapes of particulate and gaseous forms of acidic fluorides in the atmosphere by means of a double paper tape sampler. The sampler may be programmed to collect and store individual air samples obtained over time periods from several minutes to 3 h. A 30.5-m (100-ft) tape will allow unattended operation for the automatic collection of up to 600 samples.

1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are included for information only and are not considered standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 This test method provides a means of automatically separating and collecting atmospheric particulate and acidic gaseous fluoride samples.

5.2 Since the samples are collected on dry tapes, the samples are in a form which allows elution of the fluoride content with a small volume of eluent. Consequently, the method allows analyses of air samples taken for a time period as short as several minutes.

Keywords

acidic gaseous fluoride; ambient atmospheres; double paper tape sampler; fluoride; particulate fluoride; tape sampler;

To find similar documents by ASTM Volume:

11.07 (Atmospheric Analysis)

To find similar documents by classification:

13.040.20 (Ambient atmospheres Including indoor air)

To find similar documents by Federal Supply Class Code:

FSC 6810 (Chemicals)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D3266-91(2018)

Revision Level

1991 R18 EDITION

Status

Current

Modification Type

Reapproval

Publication Date

June 1, 2018

Document Type

Test Method

Page Count

6 pages

Committee Number

D22.03.02