ASTM-C635 › Standard Specification for Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This specification covers metal ceiling suspension systems used primarily to support acoustical tile or acoustical lay-in panels.
1.2 Some suspension systems incorporate locking assembly details that enhance performance by providing some continuity or load transfer capability between adjacent sections of the ceiling grid. The test methods included in this specification do not provide the means for making a complete evaluation of continuous beam systems, nor for assessing the continuity contribution to overall system performance. However, the test methods can be used for evaluating primary structural members in conjunction with secondary members that interlock, as well as with those of noninterlocking type.
1.3 While this specification is applicable to the exterior installation of metal suspension systems, the atmospheric conditions and wind loading require additional design attention to ensure safe implementation. For that reason, a specific review and approval should be solicited from the responsible architect and engineer, or both, for any exterior application of metal suspension systems in the construction of a new building or building modification.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information purposes only.
1.5 The following safety hazards caveat pertains only to the test methods described in this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
acoustical; acoustical tile; ceiling; ceiling grid; metal ceiling suspension systems; panel ceilings; ICS Number Code 91.120.20 (Acoust in buildings. Sound insulation)
To find similar documents by ASTM Volume:
04.06 (Thermal Insulation; Building and Environmental Acoustics)
To find similar documents by classification:
To find similar documents by Federal Supply Class Code:
FSC 5640 (Wallboard, Building Paper, and Thermal Insulation Materials)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ACI-318Building Code Requirements for Structural Concrete and Commentary
NFPA-25
Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
NFPA-96
Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations
Document Number
ASTM-C0635_C0635M-22
Revision Level
2022 EDITION
Status
Current
Modification Type
Revision
Publication Date
June 24, 2022
Document Type
Specification
Page Count
7 pages
Committee Number
E33.04