ASTM-C296 › Standard Specification for Asbestos-Cement Pressure Pipe (Withdrawn 2021)
The following bibliographic material is provided to assist you with your purchasing decision:
This specification covers asbestos-cement pressure pipe for use in supply lines and distribution systems that carry water under pressure. The specification also covers asbestos-cement pressure pipe for use in sewer force mains which carry sewage under pressure. Asbestos-cement pipe furnished shall conform to Classes 100, 150, and 200. The types of pipe shall be known as Type I and Type II corresponding to the chemical requirements. Hydrostatic strength; crushing strength; and flexural strength test shall be performed to conform to the specified requirements.
Scope
1.1 This specification covers asbestos-cement pressure pipe for use in supply lines and distribution systems that carry water under pressure. The specification also covers asbestos-cement pressure pipe for use in sewer force mains which carry sewage under pressure.
1.2 The text of this standard references notes and footnotes which provide explanatory material. Those notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.4 Warning—Breathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysotile asbestos, refer to “Safe Use of Chrysotile: A Manual on Preventive and Control Measures.”2
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
asbestos-cement; pipe; pressure pipe;
To find similar documents by ASTM Volume:
To find similar documents by classification:
91.100.40 (Products in fibre-reinforced cement)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C296/C296M-00(2015)
Revision Level
2000 R15 EDITION
Status
Superseded
Modification Type
Withdrawn
Publication Date
July 15, 2015
Document Type
Specification
Page Count
4 pages
Committee Number
C17.03