ASTM-C1720 › Standard Test Methods for Determining Liquidus Temperature of Waste Glasses and Simulated Waste Glasses
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 These test methods cover procedures for determining the liquidus temperature (TL) of nuclear waste, mixed nuclear waste, simulated nuclear waste, or hazardous waste glass in the temperature range from 600 °C to 1600 °C. This test method differs from Practice C829 in that it employs additional methods to determine TL. TL is useful in waste glass plant operation, glass formulation, and melter design to determine the minimum temperature that must be maintained in a waste glass melt to make sure that crystallization does not occur or is below a particular constraint, for example, 1 volume % crystallinity or T1%. As of now, many institutions studying waste and simulated waste vitrification are not in agreement regarding this constraint (1).2
1.2 Three methods are included, differing in (1) the type of equipment available to the analyst (that is, type of furnace and characterization equipment), (2) the quantity of glass available to the analyst, (3) the precision and accuracy desired for the measurement, and (4) candidate glass properties. The glass properties, for example, glass volatility and estimated TL, will dictate the required method for making the most precise measurement. The three different approaches to measuring TL described here include the following: Gradient Temperature Furnace Method (GT), Uniform Temperature Furnace Method (UT), and Crystal Fraction Extrapolation Method (CF). This procedure is intended to provide specific work processes, but may be supplemented by test instructions as deemed appropriate by the project manager or principle investigator. The methods defined here are not applicable to glasses that form multiple immiscible liquid phases. Immiscibility may be detected in the initial examination of glass during sample preparation (see 9.3). However, immiscibility may not become apparent until after testing is underway.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Significance and Use
5.1 This procedure can be used for (but is not limited to) the following applications:
(1) support glass formulation development to make sure that processing criteria are met,
(2) support production (for example, processing or troubleshooting), and
(3) support model validation.
Keywords
calibration; gradient furnace; liquidus temperature; uniform temperature furnace;
To find similar documents by ASTM Volume:
To find similar documents by classification:
81.040.10 (Raw materials and raw glass)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C1720-21
Revision Level
2021 EDITION
Status
Current
Modification Type
Revision
Publication Date
Oct. 1, 2021
Document Type
Test Method
Page Count
20 pages
Committee Number
C26.13