ASTM-C1284 › Standard Practice for Electrodeposition of the Actinides for Alpha Spectrometry
The following bibliographic material is provided to assist you with your purchasing decision:
Changes from the previous issue
A redline edition is available for this document, with all changes visible. Ask Document Center Inc. for more information.
Scope
1.1 This practice covers the preparation of separated actinide fractions for alpha spectrometry measurement.2 It is applicable to any of the actinides that can be dissolved in dilute ammonium sulfate solution. Examples of applicable actinide fractions would be an elution from an ion exchange / extraction chromatography separation or the final strip from a solvent extraction separation.
1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Significance and Use
5.1 The determination of actinide elements by alpha spectrometry measurement is an essential part of many environmental research, bioassay, and monitoring programs. Alpha spectrometry measurements identify and quantify the alpha-emitting actinide elements. A variety of separation methods will typically precede the electrodeposition of a sample for alpha spectrometry measurements. In addition to the electrodeposition procedure presented in this practice, the scientific literature contains other procedures for actinide electrodeposition.
Note 1: An alternate method for mounting actinides for alpha spectrometry measurements by coprecipitation with neodymium fluoride is described in Practice C1163.
Keywords
actinides; alpha spectrometry; electrodeposition ;; ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
To find similar documents by ASTM Volume:
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
BS-EN-55022Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
BS-EN-61010-1
Safety requirements for electrical equipment for measurement, control, and laboratory use
ISO/IEC-17025
General requirements for the competence of testing and calibration laboratories
Document Number
ASTM-C1284-18
Revision Level
2018 EDITION
Status
Current
Modification Type
Revision
Publication Date
June 1, 2018
Document Type
Practice
Page Count
3 pages
Committee Number
C26.05