ASTM-C1091 › Standard Test Method for Hydrostatic Infiltration Testing of Vitrified Clay Pipe Lines
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method defines procedures for hydrostatically testing vitrified clay pipe lines, to demonstrate the structural integrity of the installed line.
1.2 This test method is suitable for testing gravity-flow pipe lines constructed of vitrified clay pipe or combinations of clay pipe and other pipe materials.
1.3 This test method is applicable to the testing of the pipe lines only. Manholes or other structures should be tested separately.
1.4 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.
1.5 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Keywords
Acceptance criteria/testing; Acceptance criteria/testing-clay pipe/fittings; Clay pipe; Clay pipe/piping systems; Exfiltration rate; Field testing; Hydrostatic tests; Infiltration rate; Pressure testing-clay pipe; Pressure testing-pipes; Sewerlines; Standpipes; Vitrified clay pipe/fittings; Water; Water supply/distribution systems; Water test; hydrostatic infiltration/exfiltration of vitrified clay pipe lines,; test,;
To find similar documents by ASTM Volume:
To find similar documents by classification:
91.100.25 (Terracotta building products Including roofing tiles, bricks, etc.)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C1091-03AR22
Revision Level
2003A R22 EDITION
Status
Cancelled
Modification Type
Revision
Publication Date
Sept. 8, 2022
Document Type
Test Method
Page Count
2 pages
Committee Number
C04.20