ASTM-C1063 Historical Revision Information
Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster

ASTM-C1063 - 2008 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification covers the installation of lathing and furring to receive interior and exterior Portland cement-based plaster. The following materials shall be used: metal plaster basesexpanded metal lath and wire laths; accessoriessteel, PVC plastic, zinc alloy, and cornerite; channelsexternal corner reinforcement and foundation weep screed; wire; rod and strap hangers; clips; fastenersnails and screws. Hangers and cold-rolled channel main runner shall conform to the allowable spacing and spans, respectively. The following methods are discussed: installation of hangers for suspended ceilings under wood constructions, attachment of hangers to main runners, installation of main runners, installation of cross furring, metal furring for walls, lapping of metal plaster bases, spacing of attachments for metal plaster bases, application of metal plaster bases, and application of accessories.

ORDER

Scope

1.1 This specification covers the minimum requirements for lathing and furring for the application of exterior and interior portland cement-based plaster as in Specification C 926 or Specification C 841.

1.2 Where a fire resistance rating is required for plastered assemblies and constructions, details of construction shall be in accordance with reports of fire tests of assemblies that have met the requirements of the fire rating imposed.

1.3 Where a specific degree of sound control is required for plastered assemblies and constructions, details of construction shall be in accordance with official reports of tests conducted in recognized testing laboratories in accordance with the applicable requirements of Test Method E 90.

1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

Keywords

ceiling; expansion control joints; lath; plaster; screed; suspended ceiling; walls; Cement materials/applications--specifications; Cement plaster--specifications; Gypsum plaster--specifications; Gypsum products--lath (specifications); Installation--gypsum products; Metal lath; Plaster--specifications; Portland cement--specifications; Screw attachment (for metal plaster base); ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)

To find similar documents by ASTM Volume:

04.01 (Cement; Lime; Gypsum)

To find similar documents by classification:

91.100.10 (Cement. Gypsum. Lime. Mortar)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-C1063-08

Revision Level

2008 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

May 15, 2008

Document Type

Specification

Page Count

9 pages

Committee Number

C11.03