Scope

1.1 This test method covers the determination of plutonium in soils at levels of detection dependent on count time, sample size, detector, background, and tracer yield. This test method describes one acceptable approach to the determination of plutonium in soil.

1.2 This test method is designed for 10 g of soil, previously collected and treated as described in Practices C998 and C999, but sample sizes up to 50 g may be analyzed by this test method. This test method may not be able to completely dissolve all forms of plutonium in the soil matrix.

1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 A soil sampling and analysis program provides a direct means of determining the concentration and distribution of radionuclides in soil. A soil analysis program has the most significance for the preoperational monitoring program to establish baseline concentrations prior to the operation of a nuclear facility. Soil analysis, although useful in special cases involving unexpected releases, is a poor technique for assessing small incremental releases and is therefore not recommended as a method for routine monitoring releases of radioactive material. Nevertheless, because soil is an integrator and a reservoir of long-lived radionuclides, and serves as an intermediary in several of the plutonium pathways of potential importance to humans, knowledge of the concentration of plutonium in soil is essential.

Keywords

alpha spectrometry; plutonium; radiochemistry; soil;

To find similar documents by ASTM Volume:

12.01 (Nuclear Energy (I))

To find similar documents by classification:

27.120.30 (Fissile materials and nuclear fuel technology Including raw materials Radioactive wastes, see 13.030.30)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-C1001-19

Revision Level

2019 EDITION

Status

Current

Modification Type

Revision

Publication Date

Dec. 1, 2019

Document Type

Test Method

Page Count

7 pages

Committee Number

C26.05